Application Controllers
HVAC Application Controller (DAC)
The DAC range of controllers are fully programmable, Native BACnet™ Advanced Application Controllers that communicate on an RS-485 LAN using the BACnet MS/TP protocol.
The DAC is designed for a wide-range of applications that have medium local I/O requirements. It also supports BACstats and other Delta LINKnet devices. They come in a variety of I/O configurations as set out below. |
Features:
Native BACnet firmware
BACnet MS/TP communications
Supports 10 BACstat network sensors on LINKnet for room sensing and control
Delta Field Modules on LINKnet for I/O expansion
Actuator power terminal (24VAC) for each analog output
Actuator power terminals can be powered from an auxiliary transformer
Easy to mount housing
Fully programmable in GCL+
Application database can be flash loaded over the network
Controller firmware can be flash loaded over the network
Supports Modbus capability via flash loading in the field
Supports flash loading Modbus upgrades via hardware key
Derived Network Addressing (DNA) for simple integration into a standard
network architecture
Native BACnet firmware
BACnet MS/TP communications
Supports 10 BACstat network sensors on LINKnet for room sensing and control
Delta Field Modules on LINKnet for I/O expansion
Actuator power terminal (24VAC) for each analog output
Actuator power terminals can be powered from an auxiliary transformer
Easy to mount housing
Fully programmable in GCL+
Application database can be flash loaded over the network
Controller firmware can be flash loaded over the network
Supports Modbus capability via flash loading in the field
Supports flash loading Modbus upgrades via hardware key
Derived Network Addressing (DNA) for simple integration into a standard
network architecture
HVAC Application Controller (DVC)

DVC Controllers are fully programmable, Native BACnet™ Advanced Application Controllers designed for VAV applications and support the Delta BACstat and LINKnet I/O.
The damper actuator assembly is available with or without position feedback. Additional inputs and outputs can be configured as required.
The damper actuator assembly is available with or without position feedback. Additional inputs and outputs can be configured as required.
HVAC Application Controller (DFC)

DFC Controllers are fully programmable, Native BACnet™ Advanced Application Controllers designed for Fan Coil control. They communicate on an RS-485 LAN using the BACnet MS/TP protocol.
Direct 240 VAC line voltage terminal connections are provided for 1, 2 or 3 speed fans.
Room temperature can be a standard 10KΩ sensor or BACstat II, connected via a secondary LINKnet network and a 24 VAC power out connection.
Direct 240 VAC line voltage terminal connections are provided for 1, 2 or 3 speed fans.
Room temperature can be a standard 10KΩ sensor or BACstat II, connected via a secondary LINKnet network and a 24 VAC power out connection.